TSN-EX DOT MATRIX DISPLAY

  • TSN-EX DOT MATRIX DISPLAY
  • TSN-EX DOT MATRIX DISPLAY

APPLICATION AREA

TSN-EX dot matrix displays are meant to present warning or information messages for underground transportation systems to enhance safety of personnel and improve organization of transport operations. The content and colours (red or green) of displayed messages stored in the device memory is agreed upon with the user at order submission according to specific needs.

APPLICATION CONDITIONS

TSN light message boards are suitable for working areas of underground operations without the hazard of methane explosion and the ones with the ‘a’, ‘b’ and ‘c’ degree of methane explosion hazard as well as the ones classified to the ‘A’ or ‘B’ class of coal dust explosion hazard, at ambient temperatures from 0ºC to 40ºC, relative humidity up to 95% and the ‘C’ degree of corrosion aggressiveness to PN-71/H-04651). The device meets requirements of the EU ATEX Directive 2014/34/UE.

CHARACTERISTICS

Messages to be displayed can be selected locally by means of switches provided on the device enclosure. In case of remote control the messages are popped out from the memory upon commands received via intrinsically safe (IS) input contacts. Displaying of messages is controlled with use of voltage available in internal circuits of the device. The dot matrix display is furnished with an intrinsically safe relay output to control any other slave devices. The display can be mounted in whichever position and messages are always displayed correctly since cable inlets are provided at both at left-hand and right-hand side of the device. Displayed messages can be scrolled at two selectable speeds.

TECHNICAL SPECIFICATION

TYPE TSN-EX
Rated voltage

37-253V AC 50/60Hz
40-250V DC

Maximum consumption
of current
100 mA
Maximum parameters at
functional contacts
30V, 1 A DC
(intrinsically safe circuit
of ib category)
Number of messages
to be displayed
16
Range of operation
temperatures
-10°C do +40°C
Enclosure index
of protection
IP 54
Colour of displayed
messages
Red, Green
Overall dimensions (W x H x D) 665 x 255 x 130 mm
Message area (W x H) 480 x 60 mm
Weight 16kg
Maximum cross-section
of connecting conductors
0,5-4mm2
Code of explosion-proof
design (Ex marking)
I M2 Ex ib mb I Mb